Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Refract Surg ; 40(2): e98-e107, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38346118

RESUMEN

PURPOSE: To determine the prevalence of opacification of a hydrophylic intraocular lens (IOL) with hydrophobic coverage and the percentage of explantations required, determining possible risk factors associated with these opacifications. METHODS: This ambispective study enrolled 575 eyes of 296 patients (age 36 to 87 years) that underwent cataract surgery between 2010 and 2017 with implantation of different models of Lentis Mplus IOLs: LS-312-MF30, LS-313-MF15, LS-313-MF30, LU-313-MF30, and LU-313-MF30T (Oculentis GmbH). Visual, refractive, and slit-lamp biomicroscopic changes were evaluated in a long-term follow-up. The percentage of cases with IOL opacification and the percentage of cases in which IOL explantation was required due to such opacifications were calculated at each visit. Five of the explanted IOLs from this series could be analyzed by scanning electron microscopy (SEM-EDX). RESULTS: IOL opacification developed in 63 eyes (11.0%). With 95% confidence, the prevalence of IOL opacification was between 842 and 1,401 cases per 10,000 eyes. The time elapsed between surgery and the presence of IOL opacification ranged between 0 and 9.3 years (mean: 4.7 ± 2.2 years). No significant differences in terms of IOL opacification rate were found according to gender (P = .378). No significant differences were found in arterial hypertension, diabetes, hypothyroidism, or hyperthyroidism rates between eyes with or without IOL opacification (P ≥ .053). IOL explantation was needed in 9 eyes (1.57%). SEM-EDX analysis confirmed the presence of rough areas on the IOL surface containing different components, such as calcium, phosphorous, copper, or nitrogen. CONCLUSIONS: The prevalence of opacification with time in Lentis Mplus IOLs is high, with no systemic risk factors associated with this complication, suggesting that it may be attributable to the material and/or the manufacturing process. [J Refract Surg. 2024;40(2):e98-e107.].


Asunto(s)
Lentes Intraoculares , Lentes Intraoculares Multifocales , Facoemulsificación , Humanos , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Implantación de Lentes Intraoculares/efectos adversos , Prevalencia , Refracción Ocular , Lentes Intraoculares/efectos adversos , Complicaciones Posoperatorias/epidemiología
2.
J Ophthalmol ; 2023: 8814627, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37362313

RESUMEN

Purpose: The purpose of the study is to evaluate the visual and patient-reported outcomes of patients undergoing cataract surgery with implantation of an extended depth of focus (EDOF) intraocular lens (IOL) who were not primarily good candidates for multifocal IOL implantation. Methods: Retrospective analysis of data from 30 eyes (23 patients) undergoing cataract surgery with implantation of one of two EDOF IOLs (follow-up: 37.9 ± 16.2 months) and prospective observational study including 106 eyes (78 patients) implanted with one of 6 different EDOF models (follow-up: 8.0 ± 7.7 months). Patients recruited had one of the following conditions: monofocal IOL implanted in the fellow eye, previous corneal refractive surgery, mild and nonprogressive maculopathy or glaucoma, age > 75 years, amblyopia, or previous vitrectomy. Results: In the retrospective phase, significant improvements were found in uncorrected distance (UDVA), corrected distance (CDVA), and corrected near visual acuity (CNVA) (p ≤ 0.013), with a nonsignificant trend to improvement in uncorrected near visual acuity (UNVA). A total of 90% of patients were completely to moderately satisfied with the outcome achieved. In the prospective phase, significant improvements were found in UDVA, CDVA, UNVA, and CNVA (p ≤ 0.032), with a total of 85.5% of patients being completely to moderately satisfied (dissatisfaction 3.3%). In both phases, extreme difficulties were only reported by a limited percentage of patients for performing some near vision activities. Conclusions: EDOF IOLs seem to be a viable option for providing an efficient visual rehabilitation with good levels of patient satisfaction and spectacle independence associated in patients that are not primarily good candidates for multifocal IOL implantation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...